Concrete Pier Detail – New Masonry Columns
- Hinge posts super-structure installed with gates into new concrete pier prior to erection of new masonry columns
- Finished column erected after installation of super-structure with gates
- Finish grade
- Top of concrete pier 3″ below finished grade
- 48″ (increase to 60″ for 20′ wide gates)
- Top of concrete pier 26-28″ for standard 24″ square masonry column
- 12″ deep footing over undisturbed ground
- Provide 8″ square or round hole by 36″ deep for gatepost super-structure